AC Fan Control Systems





         PT/4  Automatic/Manual Fan Control Systems




                           Delta “T” Systems
                         600-PT4 Automatic Ventilation
                             Control System
                            INSTALLATION &
                           OPERATION MANUAL







                                   Project Number
                             Proprietary Material - All Rights Reserved  - Delta “T” Systems, Inc. - Copyright 2009



        Overview - The P/T4 Series Ventilation Control System   Auto Mode: The P/T4 control system start sin Auto Mode
        is a state-of-the-art digital ventilation control systems   when the engines are started. When the P/T4 system
        that has been designed and manufactured specifically   switches to Auto Mode, the exhaust fan(s) speed is
        for the rigors of the marine engine room.              adjusted automatically as the temperature increases,
        Delta “T” Systems has supplied thousands of the P/T4   measured by a sensor located within the engine room.
        Fan Control Systems to vessels all over the world, and   The intake fan(s) speed is controlled by an engine room
        has added the features that the captains and ship’s    pressure sensor. This sensor requires a sensing tube
        engineers have requested to make the PT4 the control   to the outside atmosphere as well as to the engine
        system of choice for offshore vessels of every type.   room space to measure the differential pressure. As the
                                                               engines demand greater volumes of air and the exhaust
        The P/T4 may be run in automatic or manual mode. Nor-
        mal operation is in automatic mode which goes into effect   fan(s) flow increases and as temperature rises, the
        as soon as the vessel’s engines are started. In  Automatic   intake fan(s) speed will increase to supply the required
        mode, engine room temperature and combustion air intake   airflow, thus maintaining the correct pressure and volume
        are automatically controlled to optimum levels based on   in the engine room under any conditions.
        temperature and pressure.                              Quiet Run: Upon main engine shut down, the P/T4
        The system includes a color touch screen Fan Control   ventilation control system switches to the Quiet
        Interface (FCI) and an integrated alarm output that can   Run Mode which cools the engine room down at
        be connected to a vessel’s central alarm system. Help   a user specified fixed fan speed. Once the user
        screens and simplified parameter and monitoring screens   specified temperature has been reached, the fans
        make operation and adjustment fast and easy. The       will stop thermostatically.
        P/T4 Series Systems allow the variable speed control of   Manual Mode: In addition to the two automatic
        two or more three-phase fans via a digital touch screen   modes of operation there is also a Manual Mode. The
        Fan Control Interface (FCI). Each system may be        Manual Mode allows the operator to control the fans
        configured to accept single or three phase AC input    speed and direction independently for maintenance within
        power to the ASDs (Adjustable Speed Drives), de-       the engine room or unusual situations. This mode of op-
        pending on the available power aboard the vessel.      eration is not recommended for use when underway and
                                                               the main engines are running.