Page 127 - Lewis
P. 127
126 Battery Switches and Solenoids
Electronic Solenoid Switch H.D. Solenoids, One Circuit, OFF-ON
Remote Battery Switch Normally OFF, Contacts Open
Grey Plasticized
Covering
BATTERY SWITCHES AND SOLENOIDS
24059, 24063,
24080
24117-01
FIG 3810
COLE HERSEE
These heavy, continuous-duty solenoids all have rugged hous-
FIG 1022 ings and are hardware plated to resist corrosion. 24117-01 has
a gray plasticized steel case to protect against moisture and dirt
for weather-resistant applications. The intermittent rating is at
This solenoid is hermetically sealed for maximum vibration 10 seconds ON/30 seconds OFF. They all have heavy-gauge
resistance and is waterproof. The pulse circuit requires very copper contacts, 5/16"-24 main studs, and 10-32 smaller ones.
low current draw when contact is closed. It is ignition protect- Continuous Intermittent
ed and can be used as a remote battery switch. Has a coil No. Each Volts Amps Amps
economizer. Activated by an on-off switch mounted anywhere. 24059 $40.75 12 DC 85 —
Uses No. 10 fasteners NOT included. 24063 44.15 24 DC 85 —
No. Each Amp Volt Size 24080 46.30 36 DC 85 —
9012 $289.45 450 12-24 DC 3-3/16" x 2-7/8" 24117-01 58.50 12 DC 65 750 Make – 100 Break
Cole Hersee Master Disconnect Switches
Use with alternator or generator systems to prevent electrical fires, tampering, theft & battery drain.
S.P.S.T. (SINGLE POLE, SINGLE THROW) D.P.S.T. (DOUBLE POLE, SINGLE THROW)
Switches disconnect battery circuit only and do not Switches disconnect battery circuit and alternator
disconnect alternator or generator field circuit. When or generator field circuit. Electrical contacts are
used with an alternator, engine(s) should be stopped arranged to interrupt field circuit before battery
before switching to OFF position to prevent possible circuit is broken.
alternator diode damage. COLE HERSEE
Disconnect Switch No. 82065 Blue Disconnect Switch
Enamel Aluminum
Two Positions, OFF-ON Face Plate for all Two Positions, OFF-ON
Disconnect Battery Circuit Only Disconnect Switches Disconnect Battery & Field Circuit
— See Fig. 3058
Conform to USCG 707B M284 Electrical Ratings
Safety Standard Power Switch Electrical Ratings 6 to 12 Volts DC
Section 183.410 6 to 36 Volts DC 175 Amps continuous
for ignition 175 Amps continuous 1000 Amps intermittent
protection 800 Amps intermittent 15 seconds ON,
15 seconds ON, 5 minutes OFF
5 minutes OFF FIG 3058
Ignition Protected
FIG 3059 Has a brass case with brass contacts, a die cast lever and 3/8"
diameter terminals. Brass mounting stem is 3/4" diameter by
Has a brass case and bushings with silver contacts and a die 1-13/32" long. Fits panels thru 15/16" thick.
cast lever. Two 3/8" dia. screw terminals. Brass mounting stem No. Each Volts Terminals–Type
is 3/4" dia. by 1-13/32" long. Fits panels thru 15/16" thick. M284 $69.30 6-12 DC 4 – S.P.S.T.
No. Each Volts Terminals–Type 82065 3.50 Face Plate for All Master Disconnect
M284-01 $81.80 6-36 DC 2 – S.P.S.T. Switches
Standard Package – 4