Page 127 - Lewis
P. 127

126             Battery Switches and Solenoids




                      Electronic Solenoid Switch                    H.D. Solenoids, One Circuit, OFF-ON
                          Remote Battery Switch                            Normally OFF, Contacts Open

                                                                                             Grey Plasticized
                                                                                               Covering








          BATTERY SWITCHES AND SOLENOIDS
                                                                       24059, 24063,
                                                                          24080
                                                                                                    24117-01








                                                                    FIG 3810
                                                                                                       COLE HERSEE
                                                                   These heavy, continuous-duty solenoids all have rugged hous-
               FIG 1022                                            ings and are hardware plated to resist corrosion. 24117-01 has
                                                                   a gray plasticized steel case to protect against moisture and dirt
                                                                   for weather-resistant applications. The intermittent rating is at
              This solenoid is hermetically sealed for maximum vibration  10 seconds ON/30 seconds OFF. They all have heavy-gauge
              resistance and is waterproof. The pulse circuit requires very  copper contacts, 5/16"-24 main studs, and 10-32 smaller ones.
              low current draw when contact is closed. It is ignition protect-           Continuous  Intermittent
              ed and can be used as a remote battery switch. Has a coil  No.  Each  Volts  Amps       Amps
              economizer. Activated by an on-off switch mounted anywhere.  24059  $40.75  12 DC  85    —
              Uses No. 10 fasteners NOT included.                  24063     44.15  24 DC   85         —
              No.      Each     Amp      Volt         Size         24080     46.30  36 DC   85         —
              9012    $289.45    450   12-24 DC   3-3/16" x 2-7/8"  24117-01  58.50  12 DC  65   750 Make – 100 Break

                                  Cole Hersee Master Disconnect Switches
              Use with alternator or generator systems to prevent electrical fires, tampering, theft & battery drain.


                       S.P.S.T.  (SINGLE  POLE,  SINGLE  THROW)                  D.P.S.T. (DOUBLE POLE, SINGLE THROW)
                       Switches disconnect battery  circuit only  and  do  not   Switches disconnect battery circuit and alternator
                       disconnect alternator or generator field circuit. When     or  generator field circuit.  Electrical  contacts  are
                       used with an alternator, engine(s) should be stopped      arranged to interrupt  field circuit before  battery
                       before switching to OFF position to prevent possible      circuit is broken.
                       alternator diode damage.             COLE HERSEE

                      Disconnect Switch              No.  82065  Blue               Disconnect Switch
                                                     Enamel  Aluminum
                   Two Positions, OFF-ON             Face  Plate  for  all       Two Positions, OFF-ON
                 Disconnect Battery Circuit Only     Disconnect Switches     Disconnect Battery & Field Circuit
                                                     — See Fig. 3058
              Conform to USCG        707B                                                        M284 Electrical Ratings
               Safety Standard     Power Switch  Electrical Ratings                                 6 to 12 Volts DC
               Section 183.410                  6 to 36 Volts DC                                   175 Amps continuous
                 for ignition                  175 Amps continuous                                1000 Amps intermittent
                 protection                    800 Amps intermittent                                 15 seconds ON,
                                                 15 seconds ON,                                      5 minutes OFF
                                                 5 minutes OFF      FIG 3058
                                               Ignition Protected
               FIG 3059                                            Has a brass case with brass contacts, a die cast lever and 3/8"
                                                                   diameter terminals. Brass mounting stem is 3/4" diameter by
              Has a brass case and bushings with silver contacts and a die  1-13/32" long. Fits panels thru 15/16" thick.
              cast lever. Two 3/8" dia. screw terminals. Brass mounting stem  No.  Each  Volts       Terminals–Type
              is 3/4" dia. by 1-13/32" long. Fits panels thru 15/16" thick.  M284  $69.30  6-12 DC     4 – S.P.S.T.
              No.          Each        Volts      Terminals–Type   82065      3.50   Face Plate for All Master Disconnect
              M284-01     $81.80      6-36 DC      2 – S.P.S.T.                      Switches
                                                      Standard Package – 4
   122   123   124   125   126   127   128   129   130   131   132