146                                VDO Senders


                                                  Sender and Drive Tangs
                            For Generator Tachometers and Synchronizers for Diesel Applications

                                                         FIG 4108b

                                       340-001 can be used with VDO generator tachometers and synchronizers. The generator sender is
                                       installed with its shaft connected to the injector pump or camshaft of the engine. Up to four generator
                                       tachometers and two synchronizers can be operated from one generator sender. It is important to use
              Floating Ground          the correct size drive tang for your engine. Check your engine specifications for correct drive tang
                                       size. 340-020 is for use with electronic and programmable tachometers and engine synchronizers des-
                                       ignated as inductive type.
                            Drive Tang
                                         No.              Each              Description                 Thread
                                         340-001         $210.05            Floating Ground Sender      7/8"-18
                                         340-060           26.30            Drive Tang .152"
                                         340-061*          26.10            Drive Tang .187"
                                         340-020*         134.80            Inductive/Magnetic Pick-Up Sender
                                                   For Floating/Standard Ground Information — See Fig. 4112
                     340-020                       *  WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov

                                         Engine and Gear Oil Pressure Senders
                                                         FIG 4112b
          VDO SENDERS    All Pressure Senders are 12- or 24-Volt and have 1/8-27 IPS thread unless noted. These senders work with most VDO series

                         gauges that are 10-180 ohms. Standard Ground: Single wire senders with positive lead only. Grounding occurs through the
                         sender case to common ground. Floating Ground: Two wire senders with positive and negative lead. The sender is insulat-
                         ed in the engine block and grounding occurs through the negative lead to a common ground (i.e. ground on battery). This
                         prevents the formation of a voltage leak and electrolytic corrosion. Dual Station: Dual gauge operation from a single sender.
                         "D" is stamped on side of hex nut of sender.
               Standard
                         No.
                                        Each
                                                                                IPS
                                                                                                          Ground
               Ground
                                                                                             29/4
                         360-003
                                                      Single
                                                                    80
                                        58.65
                                                                    150
                                                      Single
                         360-004       $57.85        Station        PSI        1/8-27    # on Sender      Standard
                                                                                                          Standard
                                                                                            29/12
                                                                               1/8-27
                         360-009*       71.40         Single        80         1/8-27       30/23         Standard
                         360-406        68.15         Single        400        1/8-27        38/8         Floating
                         360-410        68.15         Single        80         1/8-27        32/1         Floating
                         360-430        68.15         Single        150        1/8-27       32/14         Floating
                         360-431        68.15         Single        350        1/8-27        38/3         Floating
                         362-001        68.15         Dual          80         1/8-27         1/1         Floating
                         362-002        68.15         Dual          150        1/8-27         1/2         Floating
                         362-033        59.85         Dual          80         1/8-27         3/1         Standard
                         362-034        80.05         Dual          150        1/8-27         3/2         Standard
               Floating  362-003        68.15         Dual          350        1/8-27         2/1         Floating
               Ground    362-004        68.15         Dual          400        1/8-27         2/3         Floating
                                          NOTE: DON'T use teflon tape or pipe sealants on senders tapered threads.
                                           *2 Terminals: One to set off alarm @ 7.0 PSI and the other for pressure.
                                                      For 240-33 ohm Senders — See Fig. 7717
                                                   Temperature Senders
                                    C
                                                                 D                                 E
                                                         FIG 4109b
                                          All are 12- or 24-Volt. Refer above for ground explanation.
                                            All work with most VDO gauges that are 10-180 ohms.
                B
                                                              250°F/120°C, 6-24V
                        No.        Each      Station    Thread   Number on Sender  Ground    Terminal Connection
                        323-095   $20.95     Single    1/8-27 IPS    801/5/1     Standard     E    Packard Slip-On
                        323-416    28.00     Single    14x1.5mm      801/1/26    Standard    B     Knurled Nut
                        323-419    23.10     Single    1/2-14 IPS    801/1/16    Standard    B     Knurled Nut
                        323-420    32.05     Single    1/4-18 IPS    801/1/9     Standard    A     .250" Spade
                        323-421    28.00     Single    3/8-18 IPS    801/1/38    Standard    B     Knurled Nut
                        323-425    53.55     Single    14x1.5mm      —           Floating    C     Double .250" Spade
                        323-478    34.65     Single    1/2-14 IPS    805/1/4     Floating    C     Double .250" Spade
                        323-479    40.65     Single    3/8-18 IPS    805/1/5     Floating    C     Double .250" Spade
                        325-002    68.85     Dual*     1/4-18 IPS    805/3/1     Floating    C     Double .250" Spade
                        325-007    68.85     Dual*     3/8-18 IPS    —           Floating    C     Double .250" Spade
                 A                                           300°F/150°C, 6-24VA
                        323-485    72.50     Single    1/4-18 IPS    —           Floating    C     Double .250" Spade
               NOTE: DO NOT use teflon tape or pipe sealant on VDO tapered threads. *The "D" stamped on nut means it is a dual station sender.
                                     One (1) terminal = standard ground. Two (2) terminals = floating ground.
                                                 For 240-33 ohm Senders — See Fig. 3149