Page 194 - Vetus
P. 194

ACCESSORIES FOR BOW AND STERN THRUSTERS

       Remotely controlled battery main switch and emergency stop
       Type BPMAIN
       Ideal for use with bow thrusters, anchor windlasses or other high current consumers

       A remotely controlled battery switch is in many countries required by law. The BPMAIN can be remotely controlled electrically or
       activated by hand in an emergency. The switch should be fitted as close as possible to the battery of the bow thruster or other
       consumers, and should be placed in a position where the red emergency stop button is within reach.
       For switching on/off a control panel is supplied with pre-wired loom and multi-plugs.
       Specifications
       •  Available in 12 or 24 Volt D.C.
       •  Extension looms and control panels are optional
       •  Maximum load 250 Amps continuous or 800 Amps for 3 minutes
       Note
       When a 24 Volt bow thruster is connected to a 12 Volt circuit by a series/parallel switch, a 12 Volt
       battery main switch must be selected. When a 48 Volt bow thruster is connected to a 24 Volt circuit
       by a series/parallel switch, a 24 Volt main switch must be used.

       Type        Description
       BPMAIN12   Remotely controlled battery main switch and emergency stop 12 Volt
       BPMAIN24   Remotely controlled battery main switch and emergency stop 24 Volt                BPMAIN
       BPMEC      Extension cable 6mtr for BPMAIN
       BPMRC      Remote control for BPMAIN

       Battery main switches type BATSW

       Twin pole switching
       May be connected to either the positive or the negative electric cable. Two positions: “ON”and “OFF”. In the “OFF”position the key
       may be removed (except models 150 and 600). Provided with two M10 connectors. Model 250T is a twin pole switch to make/break
       both the positive and negative cables. Model 600 is watertight according to IP 67. Please see page 232 for technical information.

       BATSW075                            BATSW150                              BATSW250T









                        BATSW100                             BATSW250                            BATSW600

       Series/parallel switch

       Simple and time saving installation
       Bow thrusters of 352 lbf and 485 lbf (160 and 220 kgf) are only available in 24 Volt D.C.
       This series/parallel switch enables them to be connected to a 12 Volt on board supply.
       When the thruster is operated, the 12 Volt batteries are connected in series to provide
       the required 24 Volt supply. When the thruster is not operated, they are automatically
       connected in parallel and linked to the 12 Volt charging system.  This series/parallel
       switch comes with a pre-assembled auxiliary relays to ensure easy connection between
       the battery bank and the bow thruster. The charging contacts of the series/parallel
       switch have a continuous duty rating of 100 Amps and an intermittent rating of 150
       Amps at 20% duty. The series/parallel switches meet the EMC requirements.                      BPSPE

       Note
       Thruster model BOW28548D is supplied as standard with a series/parallel switch to
       permit connection to a 24 Volt battery bank. This 24 - 48 Volt series/parallel switch
       can also be ordered separately: Code BP3008.

       Type    Description
       BPSPE   Series parallel switch for 24 Volt thruster with 12 Volt charging system
       194  Maneuvering systems - Want to know more? Visit www.vetus.com
   189   190   191   192   193   194   195   196   197   198   199