PREVENTING WATER RUNNING BACK TO THE ENGINE

          Installation above or below waterline
          The cooling water injection point is crucial. If the water injection point is 6” (15 cm) or more above the waterline, the
          cooling water can be injected directly into the exhaust system. But when it is less than 6” (15 cm) above or even below the
          waterline, the cooling system can siphon water through the intake when the engine is turned off. Water can fill up the
          exhaust system and get back into the engine through the exhaust valves. This can be prevented by using a breather hose (1)
          in the cooling water system or an air vent (2).
          Calculation tool
                                                          π
          The waterlock capacity can be easily determined by   2 x (   x D² x L ) x 0,25 / 1000.000
          the following formula:                          4


          D = Internal diameter of the hose (mm)
          L = Length of hose (mm)                    Safety   Volume  25% Water   Conversion
                                                     margin         in hose    to litres

                                                                           Gooseneck           ➀ ➀   ➁ ➁
                    Gooseneck
                                                                                                       Airvent
                        Exhaust hose



                                                                                Exhaust hose          Waterline
                                                 Waterline


                   Muffler
                                     Waterlock/Muffler NLP
            Transom
           connector                                              Transom
                                                                 connector                  Waterlock/Muffler NLP
                                                                            Muffler
          Exhaust system with the water injection point “C”   Exhaust system with the water injection point “C” below
          6” (15 cm) or more above the waterline.             or less than 6” (15 cm) above the waterline.

          How to choose your perfect exhaust system
          The combination of engine and waterlock determines the optimum sound attenuation. By using this table you can choose a
          waterlock which is suitable for your engine power and exhaust diameter.

               Inlet        Exhaust
           inches     (mm)  inches     (mm)  Type LP, MF, NLP, LSS, LSL, NLPHD  Type MV  Type MGP, MGS, MGL, LSG, HPW
           1  3 /16”  30  1  3 /16”  30        13,6 hp / 10 kW           -                     -
           1  9 /16”  40  1  9 /16”  40        24,5 hp / 18 kW           -                     -
            1  3 /4”  45  1  3 /4”  45         30 hp / 22 kW             -                     -
           2  1 /64”  51  2  1 /64”  51        38 hp / 28 kW             -                     -
            2  3 /8”  60  2  3 /8”  60         53 hp / 39 kW             -                 46 hp / 34 kW
            3”     76      3”     76           86 hp / 63 kW             -                 75 hp / 55 kW
            3  1 /2”  90  3  1 /2”  90         121 hp / 89 kW       141 hp / 103 kW        105 hp / 77 kW
            4”     102     4”    102           155 hp / 114 kW      181 hp / 133 kW       136 hp / 100 kW
            4”     102     5”    127               -                     -                173 hp / 127 kW
            5”     127     5”    127           241 hp / 177 kW      281 hp / 206 kW       211 hp / 155 kW
            5”     127     6”    152               -                     -                256 hp / 188 kW
            6”     152     6”    152           345 hp / 254 kW      403 hp / 296 kW       302 hp / 222 kW
            6”     152     8”    203               -                     -                420 hp / 308 kW
            8”     203     8”    203               -                     -                539 hp / 396 kW
            8”     203    10”    254               -                     -                691 hp / 508 kW
            10”    254    10”    254               -                     -                844 hp / 620 kW

                                                        Note
             Values calculated at a back pressure of 0.1 bar. When a higher back pressure is allowed by the
              engine manufacturer, VETUS waterlocks can be used for engines with a higher output than
                                                indicated in this table.