FUEL SPLASH-STOP

       Overflowing fuel or foam collector
       Type FSA
       The fuel Splash-stop is connected right under the deck filler plate to ensure that overflowing
       fuel or foam cannot flood onto the deck. The excess diesel* or petrol fuel is collected in a
       parallel hose which functions as a reservoir, returning the fuel back into tank.
       The capacity of the reservoir is determined by the length and diameter of the hose
       (see 3 types below). Always choose the largest reservoir possible, with a maximum of
       0.58 gallons (2,2 litres). The housing and hose connection are made of anodized aluminium.
       The fill and vent lines, hose clamps and a matching stainless steel (AISI 316) deck entry should
       be ordered separately. The fuel Splash-Stop meets all the latest CE (ISO 10088) and ABYC
       standards.
                                                                                                 FSA
       FSA3816
       •  Suitable for Ø 1 /2” (38 mm) hose and  /8” (16 mm) breather line. The capacity of Ø 1 /2” (38 mm) hose is 0.27 gal. (1,1 ltr) p/mtr
                     1
                                                                           1
                                      5
       FSA5116
       •  Suitable for Ø 2” (51 mm) hose and  /8” (16 mm) breather line. The capacity of Ø 2” (51 mm) hose is 0.49 gal. (2 ltr) p/mtr
                                     5
       FSA5119
       •  Suitable for Ø 2” (51 mm) hose and  /4” (19 mm) breather line. The capacity of Ø 2” (51 mm) hose is 0.49 gal. (2 ltr) p/mtr
                                     3
                  L x W x H     Hose Ø     Breather Ø    Capacity
        Type
                   inches     inches (mm)  inches (mm)  gal.p/mtr (litr.)
        FSA3816  5 /4 x 3 /64 x 4 /64  1 /2 (38)  5 /8 (16)  0.27 (1,1)
                  3
                          49
                     25
                                 1
        FSA5116  5 /4 x 3 /64 x 4 /64  2 (51)  5 /8 (16)   0.49 (2)
                     25
                          49
                  3
        FSA5119  5 /4 x 3 /64 x 4 /64  2 (51)  3 /4 (19)   0.49 (2)
                          49
                  3
                     25
                                                                                          1. Deck entry
                                                                                          2. Reservoir / overflow hose and
                                                                                            breather line
       * Note                                                                             3. Tank breather line to outside
       A no-smell filter (for diesel only) can be fitted in the tank breather line to     4. Splash-Stop
       prevent unpleasant smells. If the filter is located well above the deck entry,     5. Hose connection
       the breather line may exit lower than the deck level if required. To prevent       6. Fuel filling hose
       expensive fuel theft, we recommend placing a FUELSAFE (see page 134) into
       the Splash-Stop.
       Type FS
       FS3816                                   FS5125
       •  Deck entry Ø 1 /2” (38 mm)            •  Deck entry Ø 2” (51 mm)
                    1
       •  Filler hose connection Ø 1 /2” / 2” (38 / 51 mm)  •  Filler hose connection Ø 2” (51 mm)
                            1
       •  Breather connection Ø  /8” (16 mm)    •  Breather connection Ø 1” (25 mm)
                           5
       FS5116
       •  Deck entry Ø 2” (51 mm)
       •  Filler hose connection Ø 1 /2” / 2” (38 / 51 mm)  Note
                            1
       •  Breather connection Ø  /8” (16 mm)    For use outside the engine room only!
                           5
                    L x W x H      Hose Ø      Breather     Deck entry
        Type                                                                       FS
                     inches     inches (mm)  inches (mm)  Ø inches (mm)
                                                              1
                   27
        FS3816    9 /32 x 4 /32 x 8 /32  1 /2  / 2 (38 / 51)  5 /8 (16)  1 /2  (38)
                                  1
                           15
                       23
        FS5116    9 /32 x 4 /32 x 8 /32  1 /2  / 2 (38 / 51)  5 /8 (16)  2 (51)              ➂       ➀
                   27
                                  1
                           15
                       23
        FS5125    9 /32 x 4 /32 x 8 /32  2 (51)  1 (25)       2 (51)
                   27
                       23
                           15
       VETUS Splash-Stop model FS is directly connected to a deck entry plate (1), with a diameter of 1 /2” (38 mm) or 2”    ➁
                                                                     1
       (51 mm) (optional equipment).
       It ensures that overflowing diesel fuel or foam will not come out of the deck entry - soiling your deck and polluting the   ➃
       water, but will be neatly caught inside the reservoir (with a capacity of approx. 2 litres). Excessive fuel will flow back into
       the main tank through connection (2).
       This connection also serves as the necessary tank ventilation. The breather line to outside is to be installed to
       connection (3).
       A VETUS diesel smell filter may be installed into this breather line as well. If the diesel smell filter is positioned well
       above the deck, the breather line may exit below the deck level, if so required. FS is supplied with connections for
       Ø 1 /2” (38 mm) or for Ø 2” (51 mm) fuel filling hose (4).
         1
       128  Fuel systems - Want to know more? Visit www.vetus.com