Page 182 - Vetus
P. 182
EXTENDED RUNTIME DC BOW AND STERN THRUSTERS
Extended runtime thrusters
Delivers a lot extra!
An extension of the basic, time-tested DC thruster, developed for use in integrated boat
control systems requiring long runtimes at high power outputs. For boats ranging from
36 to 75 feet. Extended runtime thrusters can be operated continuously for at least
7 minutes without overheating. There is no doubt that all boaters can benefit highly from
these thrusters designed for joystick docking and other more demanding applications.
• On-off, port-starboard controls
• Simple and intuitive to operate
• Simple installation, easy retrofit
• 5 models with power outputs ranging from 209 lbf (95 kgf) to 485 lbf (220 kgf)
• Battery powered at 12 and 24 Volt
• Run time 7-10 minutes continuous or combined in one hour.
• Motor technology: direct current, series wound with carbon brushes
Model
number BOW952DE BOW954DE BOW1254DE BOW1604DE BOW2204DE
(dimensions
in inches)
A 8 / ” 8 / ” 8 / ” 9 / ” 9 / ”
23
23
47
47
47
32
64
64
64
32
B 19 / ” 19 / ” 20 / ” 23 / ” 24 / ”
3
5
11
3
19
8 8 32 8 16
1
23
C 3 / ” 3 / ” 4 / ” 4 / 1 5 / ”
1
1
32 32 4 4 64
D min/max. 14 / 9 16 14 / 16 19 / ” 19 / ” 23 / ”
9
5
11
11
16
16
8
E 9 / ” 9 / ” 9 / ” 10 / ” 10 / ”
29
29
5
29
5
64
32
32
64
64
11
9
9
F 7 / ” 7 / ” 7 / ” 8 / ” 8 / ”
9
11
32 32 32 32 32
27
27
G min. 7 / ” 7 / ” 9 / ” 9 / ” 11 / ”
9
13
9
32 32 32 32 16
27
13
H 7 / ” 7 / ” 9 / ” 9 / ” 11 / ”
27
9
9
32 32 32 32 16
Specifications BOW952DE BOW954DE BOW1254DE BOW1604DE BOW2204DE
Thrust in N (kgf) (effective power output) 1050 (105) 1050 (105) 1300 (130) 1600 (160) 2200 (220)
Power kW (hp) 5.7 (8) 5.7 (8) 5,7 (8) 7 (9,5) 11 (15)
Motor, reversible D.C.
9
13
27
27
Tunnel diameter, internal, inches 7 / ” 7 / ” 9 / ” 9 / ” 11 / ”
9
32 32 32 32 16
Weight excl. tunnel, incl. packaging, in lbs 76 76 92 139 184
Weight excl. tunnel, excl. packaging, in lbs 69 69 80.4 123.5 153
Voltage, Volt D.C. 12 24 24 24 24
Current consumption, Amps. 350 350 460 450 720
Operating time - continuously, in minutes 10 10 10 10 7
- maximum per hour, in minutes 10 10 10 10 7
Main fuse, “slow blow”, Amps. 355 355 500 425 675
Batteries 12 Volt D.C., min. Ah / max. Ah @ 24 V 248/496 248/496 308/616 280/560 325/650
Battery cables**, total length of positive and 0-21/70 0-21/70 0-20/95 0-29/120 0-21/150
negative cables together, m/mm 2
Battery main switch, model BATSW / type BPMAIN 600 / 24 600 / 24 600 / 24 600 / 24 ***
** Based on VETUS battery cables
*** Currently not available in the VETUS programme