Page 158 - Vetus
P. 158
SANI-PROCESSOR
Discharge system to transport waste water into holding tank
Pumping water automatically from the shower tray or wash basin into a waste water tank is possible with the VETUS grey water
discharge system (GWDS). It has a watertight housing with a low noise discharge pump, automatic flow switch and a non-return
valve in the discharge line. You can easily pump the water into the holding tank.
Specifications
• Dimensions tank
11 /8” (300) x 6 /2” (165) x 5 /4” (145 mm)
7
1
3
(l x w x h)
• Waste water tank location up to 13 ft. (4 metres) above
GWDS unit or up to 66 ft. (20 metres) away from it
• Bottom of GWDS unit must be placed at least 2 /8”
3
(6 cm) below shower tray or washbasin
• Weight 7.7 lbs (3.5 kg)
• Pump output approx. 11.6 gal. (44 litres/min)
• Power consumption approx. 340W (12V),
350W (24V), 600W (120V), 250W (230V)
• Available for 12 or 24 Volt DC, 230 Volt/50Hz or 120
Volt/60Hz
• Maximum permissible water temperature 95°F (35ºC)
Connections
• Outlet discharge to holding tank: Ø /4” (19 mm)
3
• Inlet connections from shower or washbasin:
Ø1 /4” (32 mm) or 1 /16” (40 mm)
1
9
GWDS
Type Voltage
GWDS12 12 Volt DC
GWDS24 24 Volt DC
GWDS220 230 Volt / 50 Hz
GWDS110 120 Volt / 60 Hz
Hose connectors (1) HA1338 and
(2) HA3060 are shown on page 165.
1. Shower or washbasin connection Ø 1 /16” (40 mm)
9
2. Float switch
3. Discharge pump
4. Electric motor
5. Washbasin connection, Ø 1 /4” (32 mm) or 1 /16” (40 mm)
1
9
6. Breather
7. Waste water discharge connection: male Ø 3/4” (19 mm) o.d
8. Air conditioner connection, Ø 1/2” (12 mm)
158 Waste water systems - Want to know more? Visit www.vetus.com