Page 606 - Lewis
P. 606

Alexseal Yacht Coatings                                              605
                                                        ®


                               ALEXSEAL Finish Primer 442, Converter and Reducer
                                            ®
                          Finish
                          Primer             ALEXSEAL ® Finish Primer 442 is an epoxy based finish primer. It offers advanced adhesion
                                             qualities to various substrates while providing exceptional sanding characteristics and an
                                             improved film build. ALEXSEAL ® Finish Primer 442 is a 1 to 1 base to converter mix ratio
                                             which is ideal for a variety of customers. It is designed to be used to prime and seal old
                                             and new properly prepared stable surfaces such as gel coat, fiberglass, as well as to seal
                                             other ALEXSEAL ® primers and filler systems. ALEXSEAL ® Finish Primer 442 is designed to
                                             cure at cooler temperatures. Using this primer as a base will enhance the "Wet Look" of the
                                             ALEXSEAL ® topcoats. This product may be used above and below the waterline.

               Mixing Ratio Spray:  1 Parts by Volume  P4420 White ALEXSEAL ® Finish Primer 442 Base
                                                      P4423 Gray ALEXSEAL ® Finish Primer 442 Base
                                 1 Part by Volume     C4427 ALEXSEAL ® Finish Primer 442 Converter
                                 10-25% Reduction     R4042 ALEXSEAL ® Primer Reducer (12% Reduction Preferred)
                                                      A4429P Accelerator for Finish Primer 442
                  Application:   Viscosity (Zahn #2)  Approx. 25 sec.
                                 Fluid Nozzle Size    1.2 to 1.6 mm (.046 to 0.06) – Conventional & HVLP
                                 Atomizing Pressure   3.0 to 5.0 bar (42 to 70 PSI) – Conventional & HVLP
                                 Pot Pressure         0.7 to 1.5 bar (10 to 20 PSI) – Conventional & HVLP
                                 Airless Equipment    Tip .35 mm-60 to .43 mm-60 (.014-60 to .017-60)
                                 Airless Equipment    Pressure 3.0 to 5.0 bar (42 to 70 PSI)
                                Apply 2 to 3 coats to a wet film thickness (WFT) of 75-125 microns (3-5 mils) per coat. This will achieve
                                a dry film thickness (DFT) of 75-125 microns (3-5 mils) for a 2-coat application, and 125-200 microns (5-8
                                mils) for a 3-coat application, using 20% Primer Reducer R4042. Minimum recommended film thickness
                                before sanding is 75 microns (3 mils) DFT. Maximum recommended film thickness during a spray appli-
                                cation is 3 coats, totalling 375 microns (15 mils) WFT, or 200 microns (8 mils) DFT.
               Technical Data Sheet and MSDS Sheets available on request or visit www.alexseal.com.
                                                         FIG 1ALX
                   P = Pint  Q = Quart  G = Gallon
                  No.              Pint           Quart          Gallon          Description
                  P4420             —             $70.00        $180.00          Finish Primer 442, White (Mix Ratio: 1:1)
                  P4423             —              70.00         180.00          Finish Primer 442, Gray (Mix Ratio: 1:1)
                  C4427             —              70.00         180.00          Finish Primer 442 Converter
                  R4042             —              34.00          84.00          Epoxy Primer Reducer
                  A4429P           $46.00           —              —             Accelerator for Finish Primer 442    ALEXSEAL ®
                                                 ALL STOCKED ITEMS ARE BOLD

                                             ®
                                ALEXSEAL Super Build 302 Spray High Build Filler
                                            ALEXSEAL ® Super  Build  302  is  an  epoxy-based  high  build  primer/surfacer  which  cures
                                            into  a  smooth,  easy  to  sand,  water-resistant  coating.  ALEXSEAL ® Super  Build  302  has
                                            excellent spray characteristics and is fast drying to allow maximum efficiency while fair-
                                            ing.  The  cured  film  offers  excellent  mechanical  resistance  values.  ALEXSEAL ® Super
                                            Build 302 is used to seal ALEXSEAL ® Fairing Compound 202 and to even out imperfec-
                                            tions  remaining  after  the  filling  and  sanding  process.  It  can  also  be  used  as  a  smooth,  YACHT COATINGS
                                            non-porous surfacer prior to the application of ALEXSEAL ® Finish Primer 442. This prod-
                                            uct may be used below the waterline.
                  Mixing Ratio:  1 Part by Volume     P3002 ALEXSEAL ® Super Build 302 Base
                                1 Part by Volume      C3052 ALEXSEAL ® Super Build Converter
                                20-25% Reduction      R3040 ALEXSEAL ® Super Build Reducer
                  Application:  Viscosity (Zahn #2)   Approx. 24 sec.
                                Fluid Nozzle Size     2.2 mm (.08) – Conventional & HVLP
                                Atomizing Pressure    3.0 to 5.0 bar (42 to 70 PSI) – Conventional & HVLP
                                Pot Pressure          0.7 to 1.5 bar (10 to 20 PSI) – Conventional & HVLP
                                Airless Equipment     Tip .43 mm-60 to .60 mm-60 (.017-60 to .024-60)
                                Airless Equipment     Pressure 3.0 to 5.0 bar (42 to 70 PSI)
               Apply 2 to 3 coats to a wet film thickness (WFT) of 150-300 microns (6-12 mils) per coat. This will achieve a dry film thickness (DFT)
               of 210-420 microns (8-17 mils) for a 2-coat application, and 315-630 microns (13-25 mils) for a 3-coat application, using 10% reduc-
               tion. Minimum recommended film thickness before sanding is 210 microns (8 mils) DFT. Maximum recommended film thickness
               during a spray application is 3 coats, totalling 900 microns (36 mils) WFT, or 630 microns (25 mils) DFT.
               Technical Data Sheet and MSDS Sheets available on request or visit www.alexseal.com.
                                                         FIG 1ALX
                   Q = Quart G = Gallon
                No.                  Each                   Size               Description
                P3002G              $186.00                Gallon              Super Build 302 Spray Base (Mix Ratio: 1:1)
                C3052G               186.00                Gallon              Super Build Converter
                R3040G                84.00                Gallon              High Build Epoxy Reducer
                R3040Q                34.00                Quart               High Build Epoxy Reducer
                A4030P                46.00                 Pint               Accelerator for SuperBuild 302
   601   602   603   604   605   606   607   608   609   610   611