Page 226 - Vetus
P. 226

COMBI-GAMMA

       Type COMBI-γ
       Multi-function Inverter Charger
       The VETUS COMBI can be used as an inverter and a battery charger. In combination with a VETUS
       solar charger, the Combi-γ unit can exchange data and control the current supply, as well as the
       charging characteristics.

       This battery charger has a four-stage function: boost, absorption, float and equalize.
       Extra features
       •  Power control: Selecting the maximum input current from the shore supply or ‘genset’, to
        ensure that the circuit breaker on the shore supply or generator will not trip
       •  Power Manager: The Power Manager function controls and regulates the entire power supply.
        If you need more power, the Power Manager will automatically switch in the inverter, in order
        to supply the required power. One 3 kW Combi-γ unit will therefore supply a total of 6kW
        (3kW via the inverter function and a further 3 kW from the shore supply or the generator)
       •  Uninterrupted Power Supply (UPS): This function will switch in automatically, when the shore
        power supply fails
       •  Parallel connection: Easily connecting up to 5 COMBI units in parallel via parallel box model CGP
        (to be ordered separately)
       •  3-Phase functionality: Achieving a total output of 45kW by using 3kW COMBI’S (CG3PH)
                                                                                                    COMBI
       Remote control panel for Combi-γ
       This panel displays the following information  It also controls
       •  AC input and output voltage and current  •  Inverter, battery charger, solar charger
       •  Battery voltage, current and power consumption  ON/OFF
       •  Charging voltage and charging current levels of   •  Switching levels
        Combi-γ and solar charger                 •  Charge voltage and current
       •  UPS status                              •  Relays
       •  Multifunctional relay status            •  Parallel 3-phase configuration
       •  Alarms                                  •  AC output voltage and frequency             GAMPANEL


           VETUS “Combi-γ”, model     COMBI1512           COMBI3012          COMBI1524           COMBI3024
         Inverter
         Nominal battery voltage                  10-16 V                                 20-32 V
        input  Max. input current at
         10.5V resp. 21V and Pnom       167 A               334 A               84 A                167 A
         Voltage                                                Adjustable: 185-240 V AC
         Frequency                                            Adjustable: 50 of 60 Hz ± 0.1%
         Wave shape                                         Pure sine, total harmonic distortion < 3%
        output  Nominal power           1500 W      Continuous at cos phi =1, at a max. inverter temperature of 167°F  3000 W
                                                                               1500 W
                                                            3000 W
         Peak power                     60 min              30 min              10 min      5sec.                            1 sec.
                                      105 - 110%          120 - 130%          140 - 135%    150%                          200%
         Cos phi (power factor)                                All types of load are permitted
         Battery charger
         Voltage                                                    200-250 V AC
        input  Frequency                                         45-55 Hz or 55-65 Hz
         Cos phi (power factor)                                        1
        output Charging Current          70 A               120 A    Adjustable  40 A               70 A
         Maximum charging current
         Charging current starter battery                              4 A
         General
         Input power in UPS mode                             180 -245, switch-over time < 3 msec.
         Max. switching current UPS      16 A                30 A               16 A                30 A
         Max. current Power Control      10 A                20 A               10 A                20 A
         Multifunctional relay                                         3x
         Ambient temperature                   During storage: -22ºF to +158ºF. During use: 32ºF to +122ºF (inverter temp. 167°F)
         Relative humidity                          Max. 95%, condensation-free (all printed circuit boards are coated)
         Protection class                                              IP20


       226  Electricity on board - Want to know more? Visit www.vetus.com
   221   222   223   224   225   226   227   228   229   230   231